High-voltage power distribution assemblies

KYN61-40.5 Metal-Clad AC Enclosed Withdrawable Switchgear

An indoor power distribution device for three-phase AC systems at 50 Hz, rated at 40.5 kV. Five-prevention safety interlock system. Factory-tested, project-configured, and delivered with full technical documentation. Complies with DL 404-2007 and IEC 62271-200.

40.5kV

Rated Voltage

Max 2500A

Rated Current

Max 31.5kA

Short-circuit Current

DL 404-2007
IEC62271-200

Industrial Standard

Configuration

OEM/ Customizable

FAT Test

Delivery Standard

Technical evaluation

Key Technical Data for Project Configuration

The following table is only a framework for critical performance data for fast project evaluation. The standard configuration range is not a universal promise.

Technical Data Overview

K

Y

N

61

40.5

Metal-Clad

Withdrawable

Indoor

Design sequence number

Rated voltage (KV)

ParameterUnitValue
Rated VoltageKV40.5
Rated FrequencyHz50
Main Busbar Rated CurrentA2500
Rated Short-Circuit Breaking CurrentKA31.5
Rated Short-Circuit Making CurrentKA80
Duration of Rated Short-Circuit Withstand CurrentS4
Rated Short-Time Withstand Current (Main Circuit)KA20, 25, 31.5
Rated Peak Withstand Current (Main Circuit)KA50, 63, 80
Rated Short-Time Withstand Current (Earthing Circuit)KA27.4
Rated Peak Withstand Current (Earthing Circuit)KA69.6
Rated Power-Frequency Withstand Voltage (Short-Time)KV/1min95
Rated Lightning Impulse Withstand VoltageKV185
Rated Power-Frequency Withstand Voltage across Isolation GapkV/1min118
Mechanical EnduranceTimes3000
Protection (IP)RatingIP2X (Compartment);
IP3X(Switchgear Enclosure)
Exact evaluation depends on each project’s final electrical rating and protection levels, the model configuration selected in the engineering documents, and the final factory test report; please contact our engineers for project configuration support.

Switchgear Types & Voltage Range

Switchgear Type

Voltage Range

Common Application

Low Voltage (LV)

Up to 1 KV AC

Buildings, factories, data centres

Medium Voltage (MV)

1 kV – 35 kV

Industrial plants, substations, renewable energy plants

High Voltage (HV)

Above 35 kV

Transmission networks, power plants, substations

LV, MV and HV Switchgear Technical Comparison

Parameter

LV Switchgear

MV Switchgear

HV Switchgear

Voltage Range

Up to 1 kV

1 kV – 36 kV

Above 36 kV

Typical Applications

Buildings, Factories

Substations, Industry

Transmission Networks

Interrupting Medium

Air

Vacuum / SF6

SF6 / GIS

Rated Current

Up to 6300 A

Up to 4000 A

Up to 5000 A

Fault Current Rating

Up to 100 kA

Up to 63 kA

Up to 80 kA

Installation Type

Indoor

Indoor / Outdoor

Outdoor / GIS

Protection Complexity

Basic

Medium

Advanced

Maintenance Requirements

Low

Medium

High

Capital Cost

Low

Medium

High

Typical Users

Commercial Facilities

Utilities & Industry

Transmission Operators

Configure Your Switchgear Around Your System

Cabinet Drawing & Outline Dimensions (mm)

Component selection can be adapted to the electrical specification, protection philosophy, installation environment, and approved vendor requirements of the project.

Incoming Breaker

Selected according to rated current, fault level, and protection requirements.

Copper Busbar

Sized according to current carrying capacity, temperature rise, and short-circuit requirements.

Protection Relay

Protection and monitoring configured according to project requirements.

Metering

Provide voltage, current, power, and energy monitoring options.

Cable Compartment

Cable entry and termination arranged according to site conditions.

KYN61-40.5 Key Applications & Operating Conditions

The KYN61-40.5 metal-clad AC enclosed withdrawable switchgear is an indoor power distribution device for three-phase AC systems at 50 Hz with a rated voltage of 40.5 kV. It is used in power plants, substations, and industrial and mining enterprises for receiving and distributing electric energy, providing functions such as control, protection, and monitoring of circuits.

Standards Compliance

GB3906 “3~35kV A.C. metal-enclosed switchgear”

DL/T 404-2007 “Applies to high-voltage switchgear panels used in indoor three-phase systems with a rated voltage (highest voltage) of 3.6–40.5 kV at 50 Hz”

IEC 62271-200 ” High-voltage switchgear and controlgear – Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV”

Installation & Operating Conditions
Ambient air temperature
  • Surrounding air temperature:-10℃~+40℃.
  • The average temperature in 24 hours should not exceed 35℃.
Altitude
  • The applicable altitude should not exceed 1000m.
Atmosphere
  • The switchgear shall be installed indoors, free from fire and explosion hazards, heavy contamination, chemical corrosion, and severe vibration.
  • Earthquake intensity: ≤Magnitude 8.
Humidity
  • Relative humidity: the daily average value ≤95%, the monthly average value≤90%.
  • Average vapour pressure: the daily average value ≤ 2.2 kPa, the monthly average value ≤ 1.8 kPa.
SSE KYN61-40.5 Features
  • The cabinet structure adopts an assembled type; the circuit breaker adopts a floor-type handcart structure.
  • Equipped with a brand-new composite insulated vacuum circuit breaker, featuring good interchangeability and easy to change.
  • Interlocking among the main switch, handcart, and switchgear adopts compulsory mechanical locking mode, with the “five-prevention” safety interlock system.
  • The cable chamber is large enough to connect multiple cables.
  • Pressure relief devices are provided above the circuit breaker trolley compartment, busbar compartment, and cable compartment.
  • This equipment is finished with an imported German spray-coating system and water-based environmentally friendly coatings, with a coating uniformity deviation of no more than 5 μm. It achieves both a “zero-defect appearance” and green manufacturing, with a coating defect rate below 0.3%.

Switchgear is typically an enclosed system designed to distribute power safely, often connecting to transformers or motor control centres (MCCs), and may include devices such as variable speed drives or power distribution products. Choosing the correct switchgear involves more than matching voltage ratings.

Switchgear Applications Selection Reference

Application

Recommended Switchgear

Commercial Buildings

LV Switchgear

Data Centers

LV Switchgear

Hospitals

LV Switchgear

Manufacturing Plants

LV / MV Switchgear

Mining Operations

MV Switchgear

Renewable Energy Plants

MV Switchgear

Utility Distribution Networks

MV Switchgear

Substations

MV / HV Switchgear

Transmission Networks

HV Switchgear

Power Generation Plants

HV Switchgear

Indoor vs Outdoor Switchgear Selection Reference

Standard

Indoor Switchgear

Outdoor Switchgear

Space Availability

Limited Space

Large Sites

Environmental Protection

Excellent

Moderate

Maintenance Access

Moderate

Excellent

Initial Investment

Higher

Lower

Urban Projects

Recommended

Less Common

Utility Substations

Possible

Common

Environmental Selection Guide

Environment

Recommended Technology

Industrial Plant

Metal-Clad Switchgear

Coastal Area

Corrosion-Resistant Switchgear

Desert Region

Dust-Protected Switchgear

Urban Substation

GIS Switchgear

Renewable Energy Plant

Vacuum Switchgear

High Humidity Area

Sealed GIS Switchgear

Heavy Pollution Zone

GIS / Metal-Enclosed Switchgear

Find Your Path

Customer Role

First Question

What Details Should Care About

EPC / System Integrator

Can you meet project drawings, schedule, site standards, and grid-connection requirements?

Project delivery workflow, lead time capability, engineering case studies, scope of delivery, selection parameters, layout drawings, certifications

Distribution Contractor

Is the supplier reliable and quality consistent? Is it easy to procure, install, commission, and maintain?

Factory capability, quality control, certifications, brand components, configuration limits, installation dimensions, spare parts, manuals, after-sales terms

Plant Owner / End User

Will it run safely and reduce outage and energy-loss risk? Is it easy to maintain?

Application pain points, reliability data, power quality, maintenance convenience, case studies, warranty, remote monitoring

Distributor / Reseller

Can you support a stable product line and give technical backup? Do you offer supply continuity, customisation, and regional cooperation?

Product line coverage, regional partner policy, MOQ, OEM/ODM options, spare parts support, technical training, catalog downloads, lead time

Technical Engineer

Do rated parameters, protection scheme, and configuration match? Does it meet the local grid code and certification requirements?

Voltage/current/IP/short-circuit ratings, single-line diagrams, cabinet configuration, IEC/UL standards, test reports, downloadable data, FAQ

CUSTOMIZATION

Configured to Your Project Requirements

Align electrical, mechanical, component, and documentation options with your project requirements.
Discuss My Configuration

Electrical

  • Rated Voltage
  • Rated Current
  • Short-Circuit Level
  • Protection Scheme

Mechanical

  • Cabinet Dimensions
  • Cable Entry
  • IP Rating
  • Installation Method

Components

  • Circuit Breaker
  • Protection Relay
  • Metering
  • Communication

Documentation

  • Single-Line Diagram
  • GA Drawing
  • Wiring Diagram
  • Test Report

Tips: Final configuration is confirmed according to approved drawings, project requirements, and destination market needs.

Applications

Switchgear Projects & Applications

Representative Projects of KYN61-40.5 Metal-Clad AC Enclosed Withdrawable Switchgear.

Project Configuration Discussion
Industrial Substation applying withdrawable kyn61-40.5 switchgear

Industrial Substation

This industrial substation covers an area of around 13000 ㎡. KYN61-40.5 switchgear is widely used to receive and distribute electrical energy reliably. Its fully insulated metal-clad design and comprehensive interlocking ensure safe operation even in harsh industrial environments. With rated currents up to 4000 A and a short-circuit breaking capacity of 31.5 kA, it meets the demanding load requirements of modern industrial power systems.

10-35Kv

Voltage

~4000A

Current

China

Country

Substation

Application

  • Overline
View Details
Steel Plant applying withdrawable kyn61-40.5 switchgear

Steel Plant

At this steel plant, KYN61-40.5 switchgear supplies and protects heavy loads, including large rolling mill motors, transformers, and electric furnaces. Its robust construction withstands the high short-circuit stress and frequent operations typical of steel-making processes. The withdrawable breaker design allows fast maintenance and replacement, minimising costly production downtime.

10-35Kv

Voltage

~4000A

Current

China

Country

Heavy Industry

Application

  • Overline
View Details
Data Center applying withdrawable kyn61-40.5 switchgear

Data Center

KYN61-40.5 switchgear delivers reliable power distribution and protection for mission-critical IT loads. Its metal-clad compartments and IP3X-class enclosure effectively prevent internal faults from spreading, safeguarding power continuity. Its compact design and complete mechanical-electrical interlocks make it ideal for space-constrained, high-availability data centre facilities.

10-35Kv

Voltage

~2500A

Current

China

Country

Data Center

Application

  • Overline
View Details
Why Choose SSE Electric

Quality Control You Can See Before Shipment

Every switchgear cabinet leaving our facility must pass a five-stage quality assurance process, from raw materials to final shipment release. 

Verified Components Before They Enter Your Switchgear

We verify all purchased components, such as circuit breakers, transformers, insulators, busbar material, and auxiliary devices, against approved vendor lists and inspect them upon receipt.
01

Certificates & Test Data

Verify the certificates of conformity, type test reports, and factory test data.

02

Inspecting Structural Parts

Conduct dimensional and visual inspection of busbars, enclosures, and structural parts.

03

Testing Insulating Materials

Run sampling tests on insulating materials and other components.

04

Reject Defective Parts

Prevent defective components from entering the production line to safeguard the original reliability.

Precision Assembly That Meets the Drawing

Component assembly must strictly follow standard operating procedures to ensure worker safety while maintaining a clean, dust-free workshop environment.
01

Torquing Every Bolted Connection

Tighten all bolted joints to the specified torque values and record each connection point for traceability.

02

Verifying Clearances & Phase Sequence

Check conductor clearances, creepage distances, and phase sequence against design drawings.

03

Testing Shutters, Interlocks & Truck Mechanisms

Verify shutters, interlocks, and the truck’s mechanical performance in different positions: service, test, and withdrawn.

04

Checking Wiring Against Schematics

Check all internal wiring against schematics, including ferrule identification, terminal tightening, and earthing continuity.

Every Panel Proves Safe in Electrical Verification

Before any energization, each panel undergoes a comprehensive program of routine tests in accordance with IEC 60298 and GB 3906.
01

Measuring Main Circuit Resistance

Measure the main circuit resistance.

02

Applying Withstand Voltage Tests

Run a power-frequency withstand voltage test on the main circuit and auxiliary circuits.

03

Measuring Partial Discharge

Verify misoperation-prevention functions; detect partial discharge where specified.

04

Relays & Metering Testing

Test protection relays by secondary injection and verify metering accuracy.

Nothing Ships Only With Approval

The FAT confirms that the switchgear is built in conformity with the approved drawings, the technical specification, and all applicable standards.
01

Repeating Comprehensive Checks

Perform visual and mechanical checks; verify design drawings, test procedures, and technical documents.

02

Running Key Tests Per Standards

Conduct tests per IEC standards and project specs, including 1st/2nd injection tests and corrosion-resistance tests, etc.

03

Re-Testing Before Release

Record deviations or non-conformities during FAT, take corrective measures, and re-test until all units pass before release.

04

Preparing Before Shipping

Issue the FAT report and release certificate; clean the cabinet surface.

From Our Factory Floor to Your Site, Intact and On Time

Shipment isn’t simply switchgear dispatched. Every step follows a controlled process covering final verification, export-grade protection, document preparation, and coordinated logistics.
01

Packing for Export

Pack each cabinet in export-grade packaging with moisture proofing and shock absorbers.

02

Coordinating the Logistics

Manage the entire transport chain —booking, routing, and customs coordination—to ensure on-time delivery to the site.

03

Documentation Preparing

Photograph and record packaging, loading, and container sealing.

04

Delivering the Full Dossier

Complete the documentation package for every shipment, including the spare parts list.

Specific Visual Evidence

Global Electrical Industry Partners & Customers

Provide customers with production line technical consultation, engineering design, design selection, engineering budgeting, factory automation, full-process training, installation, commissioning, and turnkey solutions for the entire factory.

Engineer Online

+86 123 456 7890

Quality & Compliance

Standards & Certifications

Use this space to add a medium-length description. Be brief and give enough information to earn their attention.

  • IEC 62271-200
  • IS09001
  • CE Certificate
  • FAT Report
  • CE Certificate
  • FAT Report

Sample documents available upon request.

View Full Certificates
OEM & ODM WORKFLOW

From Project Requirements to Delivered Electrical Equipment

Confirm final electrical ratings and configurations against the project specification and approved engineering documents.

Built for Fast, Safe Grid & Plant Integration

Find answers to common questions, or share your project details with our technical team for tailored support.

Talk to Our Technical Butler Team

Send the information you already have. We will help organise the rest.

* fields help us return a quick response to you as soon as possible.

The switchgear normally uses a compatible 40.5 kV vacuum circuit breaker on a withdrawable truck. The exact breaker model, rated current, short-circuit breaking capacity, operating mechanism, and electrical interface must be confirmed with the manufacturer.

It is generally designed and tested in accordance with applicable IEC standards for high-voltage switchgear, particularly IEC 62271-200, or the corresponding Chinese standards, like GB3906 and DL/T 404-2007. Any local requirements should be specified with our engineers before the contract.

Warranty terms are defined in the contract: all products have a 24-month standard warranty. Our 24/7 technical hotline and after-sales customer service can provide immediate remote support. We also offer operation and maintenance training. We can arrange global dispatch of critical spare parts within 48 hours. Engineers are available for on-site supervision or remote consultation.

Email

Info@businessname.com

WhatsApp/WeChat

+86 123 456 78900

Business Hours

9:00 AM – 6:00 PM GMT+08:00

Location

Henan Province, China