High-voltage power distribution assemblies

HXGN-12 Box-Type Fixed Metal-Enclosed Ring Main Unit

Lightweight and compact design with flexible expansion capability. Five-prevention safety interlock system. Maintenance-free Operation for 20 Years. IEC 62271-200 Standards Compliance.

Get Support from EngineersRequest A Technical Quote
12Kv

Rated Voltage

630A

Rated Current

Max 50KA

Rated Short-circuit Current

IEC 62271-200

Industrial Standard

Configurations

OEM Customizable

FAT Test

Delivery Standard

Technical evaluation

Key Technical Data for Project Configuration

The following table is only a framework for critical performance data for fast project evaluation. The standard configuration range is not a universal promise.

Technical Data Overview

H

X

G

N

12

Ring Main Unit

Box-type

Fixed

Indoor

Rated Voltage

ParameterUnitValue
Rated VoltageKV12
Rated FrequencyHz50
Rated Insulation Level1 min Power Frequency
Withstand Voltage Rated
Phase-to-Phase GapKV42
Phase-to-Earth GapKV48
Lightning Impulse
Withstand Voltage
(Peak)
Phase-to-Phase GapKV75
Phase-to-Earth GapKV85
Main Busbar Rated CurrentA630
Branch Bar Rated CurrentA630
Rated Short-time Withstand Current (4s)KA20
Rated Withstand Current (Peak Value)KA50
Rated Short-Circuit Breaking CurrentKA31.5
Protection (IP)RatingShell IP rating based on the actual installation environment. For dusty or humid environments, we can optimise enclosure protection, ventilation, and anti-condensation design accordingly.IP3X (Minimum Customisation Requirement)
Exact evaluation depends on each project’s final electrical rating and protection levels, the model configuration selected in the engineering documents, and the final factory test report; please contact our engineers for project configuration support.

Switchgear Types & Voltage Range

Switchgear Type

Voltage Range

Common Application

Low Voltage (LV)

Up to 1 KV AC

Buildings, factories, data centres

Medium Voltage (MV)

1 kV – 35 kV

Industrial plants, substations, renewable energy plants

High Voltage (HV)

Above 35 kV

Transmission networks, power plants, substations

LV, MV and HV Switchgear Technical Comparison

Parameter

LV Switchgear

MV Switchgear

HV Switchgear

Voltage Range

Up to 1 kV

1 kV – 36 kV

Above 36 kV

Typical Applications

Buildings, Factories

Substations, Industry

Transmission Networks

Interrupting Medium

Air

Vacuum / SF6

SF6 / GIS

Rated Current

Up to 6300 A

Up to 4000 A

Up to 5000 A

Fault Current Rating

Up to 100 kA

Up to 63 kA

Up to 80 kA

Installation Type

Indoor

Indoor / Outdoor

Outdoor / GIS

Protection Complexity

Basic

Medium

Advanced

Maintenance Requirements

Low

Medium

High

Capital Cost

Low

Medium

High

Typical Users

Commercial Facilities

Utilities & Industry

Transmission Operators

Configure Your Switchgear Around Your System

Cabinet Drawing & Outline Dimensions (mm)

Component selection can be adapted to the electrical specification, protection philosophy, installation environment, and approved vendor requirements of the project.

Incoming Breaker

Selected according to rated current, fault level, and protection requirements.

Copper Busbar

Sized according to current carrying capacity, temperature rise, and short-circuit requirements.

Protection Relay

Protection and monitoring configured according to project requirements.

Metering

Provide voltage, current, power, and energy monitoring options.

Cable Compartment

Cable entry and termination arranged according to site conditions.

HXGN-12 Key Applications & Operating Conditions

HXGN-12 is a box-type fixed metal-enclosed ring main unit (hereinafter referred to as “RMU”). It is a complete set of A.C. high-voltage electrical equipment rated at 12 kV / 50 Hz. It is used for power distribution, power control, and protection of electrical equipment. Compact and lightweight, the fully assembled structure allows flexible combination and installation, thus enabling unlimited expansion and extension. It is widely used in the construction and renovation of urban power grids, industrial and mining enterprises, high-rise buildings, and commercial complexes.

Standards Compliance

GB3906 “3~35kV A.C. metal-enclosed switchgear”

IEC 62271-200 ” High-voltage switchgear and controlgear – Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV”

Installation & Operating Conditions

Ambient air temperature
  • Surrounding air temperature:-15℃~+40℃.
Altitude
  • The applying altitude should not exceed 1000m.
Ambient Conditions
  • Free from corrosive and flammable gases.
  • Earthquake intensity: ≤Magnitude 8.
Humidity
  • Relative humidity: the daily average value ≤95%, the monthly average value≤90%.
  • Average vapour pressure: the daily average value ≤ 2.2 kPa, the monthly average value ≤ 1.8 kPa.
SSE HXGN-12 Features
  • Equipped with a ±0.1mm high-precision line control system, it achieves millimetre-level control of switchgear bending and assembly, achieving a component standardisation rate of ≥99% and a dimensional qualification rate exceeding 99.5%.
  • The cabinet body is constructed from 316L stainless steel with a nano-ceramic coating and is processed, formed, and assembled using high-strength bolts, nuts, and rivets.
  • Compatible with various brands of circuit breakers, including components from brands such as ABB and Siemens, including the domestically produced ZN85-40.5 (3AV3) vacuum circuit breaker and Schneider’s HVX series, to meet diverse user needs.
  • Metal partitions separate each functional compartment in the switchgear. A clearly visible front-door inspection window provides instant visual confirmation.
  • Maintenance-free design with front-access only; Major inspections required only after 5 years or 100 operations.
  • Supporting both manual and electrical operation; Five-prevention safety interlock system to reduce risks for unconscious operator errors.

Switchgear is typically an enclosed system designed to distribute power safely, often connecting to transformers or motor control centres (MCCs), and may include devices such as variable speed drives or power distribution products. Choosing the correct switchgear involves more than matching voltage ratings.

Switchgear Applications Selection Reference

Application

Recommended Switchgear

Commercial Buildings

LV Switchgear

Data Centers

LV Switchgear

Hospitals

LV Switchgear

Manufacturing Plants

LV / MV Switchgear

Mining Operations

MV Switchgear

Renewable Energy Plants

MV Switchgear

Utility Distribution Networks

MV Switchgear

Substations

MV / HV Switchgear

Transmission Networks

HV Switchgear

Power Generation Plants

HV Switchgear

Indoor vs Outdoor Switchgear Selection Reference

Standard

Indoor Switchgear

Outdoor Switchgear

Space Availability

Limited Space

Large Sites

Environmental Protection

Excellent

Moderate

Maintenance Access

Moderate

Excellent

Initial Investment

Higher

Lower

Urban Projects

Recommended

Less Common

Utility Substations

Possible

Common

Environmental Selection Guide

Environment

Recommended Technology

Industrial Plant

Metal-Clad Switchgear

Coastal Area

Corrosion-Resistant Switchgear

Desert Region

Dust-Protected Switchgear

Urban Substation

GIS Switchgear

Renewable Energy Plant

Vacuum Switchgear

High Humidity Area

Sealed GIS Switchgear

Heavy Pollution Zone

GIS / Metal-Enclosed Switchgear

Find Your Path

Customer Role

First Question

What Details Should Care About

EPC / System Integrator

Can you meet project drawings, schedule, site standards, and grid-connection requirements?

Project delivery workflow, lead time capability, engineering case studies, scope of delivery, selection parameters, layout drawings, certifications

Distribution Contractor

Is the supplier reliable and quality consistent? Is it easy to procure, install, commission, and maintain?

Factory capability, quality control, certifications, brand components, configuration limits, installation dimensions, spare parts, manuals, after-sales terms

Plant Owner / End User

Will it run safely and reduce outage and energy-loss risk? Is it easy to maintain?

Application pain points, reliability data, power quality, maintenance convenience, case studies, warranty, remote monitoring

Distributor / Reseller

Can you support a stable product line and give technical backup? Do you offer supply continuity, customisation, and regional cooperation?

Product line coverage, regional partner policy, MOQ, OEM/ODM options, spare parts support, technical training, catalog downloads, lead time

Technical Engineer

Do rated parameters, protection scheme, and configuration match? Does it meet the local grid code and certification requirements?

Voltage/current/IP/short-circuit ratings, single-line diagrams, cabinet configuration, IEC/UL standards, test reports, downloadable data, FAQ

CUSTOMIZATION

Configured to Your Project Requirements

Electrical, mechanical, component, and documentation options can be aligned with your project requirements.
Discuss My Configuration
Electrical
  • Rated Voltage
  • Rated Current
  • Short-Circuit Level
  • Protection Scheme
Mechanical
  • Cabinet Dimensions
  • Cable Entry
  • IP Rating
  • Installation Method
Components
  • Circuit Breaker
  • Protection Relay
  • Metering
  • Communication
Documentation
  • Single-Line Diagram
  • GA Drawing
  • Wiring Diagram
  • Test Report

Tips: Final configuration is confirmed according to approved drawings, project requirements, and destination market needs.

Applications

Switchgear Projects & Applications

Representative projects of HXGN-12 Box-Type Fixed Metal-Enclosed Ring Main Unit.

Project Configuration Discussion
Urban Power Grid Construction

Power distribution and monitoring for urban infrastructure networks.

0.4-12Kv

Voltage

~4000A

Current

China

Country

Utility

Application

  • Overline
View Details
Industrial and Mining Enterprises

Reliable power supply and protection for heavy-duty operations in the industrial sector.

6-35Kv

Voltage

~4000A

Voltage

China

Country

Industry

Application

  • Overline
View Details
Official Buildings and Commercial Complexes

Space-constrained power distribution solutions for commercial complexes and high-rise buildings.

0.4-25Kv

Voltage

~2500A

Voltage

China

Country

Buildings

Application

  • Overline
View Details
Why Choose SSE Electric

Quality Control You Can See Before Shipment

Every switchgear cabinet that leaves our facility must pass through a five-stage quality assurance process, from raw materials to final release for shipment. 

Verified Components Before They Enter Your Switchgear

All purchased components, such as circuit breakers, transformers, insulators, busbar material, and auxiliary devices, are verified against approved vendor lists and inspected upon receipt.
01
Verifying Certificates & Test Data

Verify the certificates of conformity, type test reports, and factory test data.

02
Inspecting Structural Parts

Conduct dimensional and visual inspection of busbars, enclosures, and structural parts.

03
Testing Insulating Materials

Run sampling tests on insulating materials and other components.

04
Rejecting Non-Conforming Parts

Prevent defective components from entering the production line to safeguard the original reliability.

Precision Assembly That Meets the Drawing

Component assembly must strictly follow standard operating procedures to ensure worker safety while maintaining a clean, dust-free workshop environment.
01
Torquing Every Bolted Connection

Tighten all bolted joints to specified torque values, with each connection point recorded for traceability.

02
Verifying Clearances & Phase Sequence

Check conductor clearances, creepage distances, and phase sequence against design drawings.

03
Testing Shutters, Interlocks & Truck Mechanisms

Verify shutters, interlocks, and the truck’s mechanical performance in different positions: service, test, and withdrawn.

04
Checking Wiring Against Schematics

Check all internal wiring against schematics, including ferrule identification, terminal tightening, and earthing continuity.

Every Panel Proves Safe in Electrical Verification

Before any energization, each panel undergoes a comprehensive program of routine tests in accordance with IEC 60298 and GB 3906.
01
Measuring Main Circuit Resistance

Measure the resistance of the main circuit.

02
Applying Withstand Voltage Tests

Run a power-frequency withstand voltage test on the main circuit and auxiliary circuits.

03
Measuring Partial Discharge

Verify misoperation-prevention functions; detect partial discharge where specified.

04
Testing Relays & Verifying Metering

Test protection relays by secondary injection and verify metering accuracy.

Nothing Ships Only With Approval

The FAT confirms that the switchgear is built in conformity with the approved drawings, the technical specification, and all applicable standards.
01
Repeating Comprehensive Checks

Perform visual and mechanical checks; verify design drawings, test procedures, and technical documents.

02
Running Key Tests Per Standards

Conduct tests per IEC standards and project specs, including withstand tests, primary/secondary injection tests, and corrosion resistance tests.

03
Re-Testing Before Release

Record deviations or non-conformities during FAT, take corrective measures, and re-test until all units pass before release.

04
Preparing Before Shipping

Issue the FAT report and release certificate; clean the cabinet surface.

From Our Factory Floor to Your Site, Intact and On Time

Shipment isn’t simply switchgear dispatched. Every step follows a controlled process covering final verification, export-grade protection, document preparation, and coordinated logistics.
01
Packing for Export

Pack each cabinet in export-grade packaging with moisture proofing and shock absorbers.

02
Coordinating the Logistics

Manage the entire transport chain —booking, routing, and customs coordination—to ensure on-time delivery to the site.

03
Documenting Before Dispatch

Photograph and record packaging, loading, and container sealing.

04
Delivering the Full Dossier

Prepare a complete documentation package for every shipment: routine test reports, FAT protocol, operating manuals, and spare parts list.

Specific Visual Evidence

Global Electrical Industry Partners & Customers

Provide customers with production line technical consultation, engineering design, design selection, engineering budgeting, factory automation, full-process training, installation, commissioning, and turnkey solutions for the entire factory.

Engineer Online

+86 123 456 7890

Quality & Compliance

Standards & Certifications

  • IEC 62271-200
  • IS0 9001
  • CE Certificate
  • FAT Report
  • CE Certificate
  • FAT Report

Sample documents available upon request.

View Full Certificates

Built for Fast, Safe Grid & Plant Integration

* fields help us return a quick response to you as quickly as possible.

Yes. We can tailor configurations to your voltage, electricity power quality, and specific requirements. We have experience in designing customised solutions for power generation plants, industrial workshops, data centres, hospitals, etc. We have helped numerous enterprises and institutions resolve issues such as voltage fluctuations, low power factor, and harmonic distortion.

Standard units can be delivered within 3-4 weeks from order confirmation. Custom configurations typically require 5-6 weeks. We offer phased delivery for large projects. We maintain a 98% on-time delivery rate, well above the industry average.

Warranty terms are defined in the contract: all products have a 24-month standard warranty. Our 24/7 technical hotline and after-sales customer service can provide immediate remote support. We also offer operation and maintenance training. We can arrange global dispatch of critical spare parts within 48 hours. Engineers are available for on-site supervision or remote consultation.

Email

Info@businessname.com

WhatsApp/WeChat

+86 123 456 78900

Business Hours

9:00 AM – 6:00 PM GMT+08:00

Location

Henan Province, China